UPS PASCAL ONLINE UPS – H SERIES

H-Series

PASCAL H Series

PASCAL H Series On-Line UPS is designed with latest technology, making it distinguished by its performance and reliability. The input range is extraordinary wide from 118V to 300V so that the UPS can still run well in areas of poor utility and be robust in various applications. It also eliminates unnecessary battery discharges to prolong the life expectancy of battery. The rectifier stage of H Series implements high frequency, PWM, and power factor correction method. Therefore, the input current is purely sine wave, and power factor can be over 95%.

PASCAL H Series have very small harmonic current drawn from the utility. That is, it generates no interference to the utility. Beside, the inverter of the unit adopts newest and tough IGBT, high frequency PWM method. So it can response quickly to load change, especially the impressing capability of starting computer load. All power stages are carefully designed to optimal efficiency so as to save the user’s running cost, and minimize heat dissipation. The unit, controlled by the innovative software programs, can self-diagnose all the time and provides various status and data displayed clearly on the panel.

Tower and Rack Models

Tower and Rack models are both available. Tower model can minimize occupied space. Rack mount model can fit in the equipment rack to make the server room neat and clean. Rack mount model UPS come with the same size battery bank which matches the UPS.

6KVA-20KVA N+ 1 Parallel Redundancy

6KVA-20KVA, specially designed to provide redundant power protection solution, is able to perform parallel up to 3 UPS systems. With the high frequency PWM technology, the UPS attains high input power factor over 95% and avoids significant harmonic interference on the power workshop. The higher efficiency of the inverter enhances the overall efficiency of UPS and reduces the noise of the inverter as well.

Multiple interfaces Cards

With a Multi-interface slot and an additional Multi-interface card, various communications combinations are selectable. Including RS232, SNMP, RS485, AS-400, Modbus, USB, Dry Contact and customized interfaces. All interfaces enable at the same time.

Iklan

UPS LAPLACE POSITRON SERIES

Image

UPS LAPLACE POSITRON SERIES

MULAI DARI 600 VA – 1000 VA

Model
Backup Time *
Battery SLA
Net Weight
(KGs)
Dimensions
Positron 600
13 min
12 V / 7 AH x 1 pc 3.1 213x75x185
Positron 1000 30 min 12 V / 7 AH x 2 pcs 6.5 281.4x84x240.5
a. Offline Design
b. Microprocessor control guanrantees high reliability
c. High Frequency technology design brings compact size and light weight
d. Horizontal and vertical positioning capability suits varity of working space
e. Auto Restart while AC Recovery for Positron 600
f. Simple Installation and Operation
g. Short circuit and overload protection

UPS LAPLACE PHASOR

Image

UPS LAPLACE PHASOR SERIES

TERSEDIA UKURAN 600 VA – 2200 VA

Model
Back Up time
Recharge Time
Net Weight
(KGs)
Dimension
(mm) W x D x H
Phasor 600
17
8 hours
  6
330x100x140
Phasor 1200 23 8 hours 13.8 368x140x180
Phasor 2200 26 8 hours 16 368x140x180
a. Line Interactive Design
b. Automatic Voltage Regulator
c. Fully Digitized Microprocessor Controlled
d. Energy Saving
e. Short Circuit and Overload Protection
f. Tel/Modem/Internet (RJ-11) Protection
g. Smart RS-232 Communication Port

UPS ICA SIN 2100C

ITEM UNIT SPECIFICATION REMARKS
 MODEL SIN2100C
 CAPACITY VA/W 3100/2015
AC INPUT VOLTAGE V 185 – 250
FREQUENCY Hz 50 ± 5%
PROTECTION NO FUSE BREAKER
DC INPUT VOLTAGE V 120
INTERNAL BATTERY 10 x 12V, 7 AH SEALED LEAD ACID BATTERY
PROTECTION NO FUSE BREAKER
CHG TOPOLOGY SWITCHING REGULATION
FLOATING VOLTAGE V 136
INVERTER OUTPUT WAFE FORM SINUSOIDA
DISTORTION < 3% THD LOAD FROM 0 – 100%
TOPOLOGY PULSE WIDTH MODULATION (PWM)
VOLTAGE V 220 ± 2%
FREQUENCY Hz 50 ± 1%
EFFICIENCY % ± 85 AT FULL LOAD
TRANSFER TIME WHEN AC INPUT LOSS ms 0 ON-LINE/CONTINUOUS
STATIC TRANSFER SWITCH ms 2 ms FROM INVERTER TO BY-PASS, 0 ms BACK TO INVERTER
BACK UP TIME min 10 AT NOMINAL LOAD
BUZZER UPS IN BY-PASS CONDITION INTERMITTENT SOUND WITH 30 SECONDS INTERVAL WARNING THAT UPS IN BYPASS CONDITION
AC INPUT ABNORMAL INTERMITTENT SOUND WITH 4 SECONDS INTERVAL AC INPUT LOSS OR LESS THEN 185 V
BATTERY LOW INTERMITTENT SOUND WITH 1 SECOND INTERVAL
OPERATION TEMPERATURE °C 0- 40
DIMENSION mm 630 x 265 x 610 D x W x H
WEIGHT Kg 85

UPS ICA CT 682B

ITEM UNIT SPECIFICATION REMARKS
MODEL CT682B
CAPACITY VA/W 1200/600 MAXIMUM
AC INPUT VOLTAGE V 160 – 250
CURRENT A 2.9 MAX. LOAD & CHARGER
FREQUENCY Hz 50 ± 3
PROTECTION A 5 FUSE
DC INPUT INTERNAL BATTERY 2 x 12V, 7 AH SEALED LEAD ACID BATTERY
PROTECTION A 40
ERTER

OUTPUT

 

WAVE FORM SYNTHESIZED SINEWAVE (STEP WAVE) PWM
VOLTAGE V 220 ± 5%
FREQUENCY Hz 50
EFFICIENCY % >80
CHG TYPE CONSTANT VOLTAGE
VOLTAGE V 27
CURRENT A 1.5
TRANSFER TIME ms ≤ 4
BACKUP TIME min 10 NORMAL LOAD
INDICATOR LED & BUZZER REFER TO CONDITION TABLE
OPERATION TEMPERATURE °C 0 – 40
DIMENSION mm 390 x 145 x 195 D x W x H
WEIGHT Kg 15