UPS ICA SIN 3100C

ITEM UNIT SPECIFICATION REMARKS
 MODEL SIN3100C
 CAPACITY VA/W 5000/3250
AC INPUT VOLTAGE V 185 – 250
FREQUENCY Hz 50 ± 5%
PROTECTION NO FUSE BREAKER
DC INPUT VOLTAGE V 192
INTERNAL BATTERY 16 x 12V, 7 AH SEALED LEAD ACID BATTERY
PROTECTION NO FUSE BREAKER
CHG TOPOLOGY SWITCHING REGULATION
FLOATING VOLTAGE V 217,6
INVERTER OUTPUT WAFE FORM SINUSOIDA
DISTORTION < 3% THD LOAD FROM 0 – 100%
TOPOLOGY PULSE WIDTH MODULATION (PWM)
VOLTAGE V 220 ± 2%
FREQUENCY Hz 50 ± 1%
EFFICIENCY % ± 85 AT FULL LOAD
TRANSFER TIME WHEN AC INPUT LOSS ms 0 ON-LINE/CONTINUOUS
STATIC TRANSFER SWITCH ms 2 ms FROM INVERTER TO BY-PASS, 0 ms BACK TO INVERTER
BACK UP TIME min 10 AT NOMINAL LOAD
BUZZER UPS IN BY-PASS CONDITION INTERMITTENT SOUND WITH 30 SECONDS INTERVAL WARNING THAT UPS IN BY-PASS CONDITION
AC INPUT ABNORMAL INTERMITTENT SOUND WITH 4 SECONDS INTERVAL AC INPUT LOSS OR LESS THEN 185 V
BATTERY LOW INTERMITTENT SOUND WITH 1 SECOND INTERVAL
OPERATION TEMPERATURE °C 0 – 40
DIMENSION mm 630 x 265 x 690 D x W x H
WEIGHT Kg 110

 

Iklan

UPS ICA SIN 2100C

ITEM UNIT SPECIFICATION REMARKS
 MODEL SIN2100C
 CAPACITY VA/W 3100/2015
AC INPUT VOLTAGE V 185 – 250
FREQUENCY Hz 50 ± 5%
PROTECTION NO FUSE BREAKER
DC INPUT VOLTAGE V 120
INTERNAL BATTERY 10 x 12V, 7 AH SEALED LEAD ACID BATTERY
PROTECTION NO FUSE BREAKER
CHG TOPOLOGY SWITCHING REGULATION
FLOATING VOLTAGE V 136
INVERTER OUTPUT WAFE FORM SINUSOIDA
DISTORTION < 3% THD LOAD FROM 0 – 100%
TOPOLOGY PULSE WIDTH MODULATION (PWM)
VOLTAGE V 220 ± 2%
FREQUENCY Hz 50 ± 1%
EFFICIENCY % ± 85 AT FULL LOAD
TRANSFER TIME WHEN AC INPUT LOSS ms 0 ON-LINE/CONTINUOUS
STATIC TRANSFER SWITCH ms 2 ms FROM INVERTER TO BY-PASS, 0 ms BACK TO INVERTER
BACK UP TIME min 10 AT NOMINAL LOAD
BUZZER UPS IN BY-PASS CONDITION INTERMITTENT SOUND WITH 30 SECONDS INTERVAL WARNING THAT UPS IN BYPASS CONDITION
AC INPUT ABNORMAL INTERMITTENT SOUND WITH 4 SECONDS INTERVAL AC INPUT LOSS OR LESS THEN 185 V
BATTERY LOW INTERMITTENT SOUND WITH 1 SECOND INTERVAL
OPERATION TEMPERATURE °C 0- 40
DIMENSION mm 630 x 265 x 610 D x W x H
WEIGHT Kg 85

UPS ICA SIN 1100C

ITEM UNIT SPECIFICATION REMARKS
 MODEL SIN1100C
 CAPACITY  VA/W  1600/1040
AC INPUT VOLTAGE V 185 – 250
FREQUENCY Hz 50 ± 5%
PROTECTION NO FUSE BREAKER
DC INPUT VOLTAGE V 84
INTERNAL BATTERY 7 x 12V, 7AH SEALED LEAD ACID BATTERY
PROTECTION NO FUSE BREAKER
 CHG TOPOLOGY  SWITCHING REGULATION
FLOATING VOLTAGE  V  95.2
INVERTER OUTPUT WAFE FORM SINUSOIDA
DISTORTION < 3% THD LOAD FROM 0-100%
TOPOLOGY PULSE WIDTH MODULATION (PWM)
VOLTAGE V 220 ± 2%
FREQUENCY Hz 50 ± 1%
EFFICIENCY % ± 85 AT FULL LOAD
TRANSFER TIME WHEN AC INPUT LOSS ms 0 ON-LINE/CONTINUOUS
STATIC TRANSFER SWITCH ms 2 ms FROM INVERTER TO BY-PASS, 0 ms BACK TO INVERTER
BACK UP TIME min 10 AT NOMINAL LOAD
BUZZER UPS IN BY-PASS CONDITION INTERMITTENT SOUND WITH 30 SECONDS INTERVAL WARNING THAT UPS IN BYPASS CONDITION
AC INPUT ABNORMAL INTERMITTENT SOUND WITH 4 SECONDS INTERVAL AC INPUT LOSS OR LESS THEN 185 V
BATTERY LOW INTERMITTENT SOUND WITH 1 SECOND INTERVAL
OPERATION TEMPERATURE °C 0 – 40
DIMENSION mm 510 x 205 x 450 D x W x H
WEIGHT Kg 50